2014-06-23 - 13332 - Service Request - RunTime Testing from WilcomDev to POLCA #POLCAApplication

2014-06-23 - 13332 - Service Request - RunTime Testing from WilcomDev to POLCA

Problem Summary


Modified the QA Ecalc package and ConnString.xml file to help with Wilcom Tape data get imported into POLCA QA with correct data.

Admin Info



Purpose
RunTime Testing from WilcomDev to POLCA
Requested by
Daniela
Issue Date
06-23-2014
Resolved by
Venkat A
Resolved Date
06-23-2014
Document Status
WIP

Detailed Problem Description

(Include Screen Shots if required )

NEC reported that Stitch count is coming correct as that is in Wilcom Database.


Solution Analysis and Recommendations

(Include Screen Shots if required)

Earlier the packages are pointing to other Database servers and databases. But now they are checking the Wilcom data in another database server. So the is not matching with it.
So Database server and connections need to be changed to the database which NEC is pointing to compare.

Resolution


Updated the database name in Ecalc package and requested NEC to change the Connection string to point the new Database server which they are currently using to compare the data.

Release Information


13332 - Release Notes - RunTime Testing from WilcomDev to POLCA