2014-06-23 - 13332 - Service Request - RunTime Testing from WilcomDev to POLCA #POLCAApplication
2014-06-23 - 13332 - Service Request - RunTime Testing from WilcomDev to POLCA
Problem Summary
Modified the QA Ecalc package and ConnString.xml file to help with Wilcom Tape data get imported into POLCA QA with correct data.
Admin Info
Purpose
|
RunTime Testing from WilcomDev to POLCA
|
Requested by
|
Daniela
|
Issue Date
|
06-23-2014
|
Resolved by
|
Venkat A
|
Resolved Date
|
06-23-2014
|
Document Status
|
WIP
|
Detailed Problem Description
(Include Screen Shots if required )
NEC reported that Stitch count is coming correct as that is in Wilcom Database.
Solution Analysis and Recommendations
(Include Screen Shots if required)
Earlier the packages are pointing to other Database servers and databases. But now they are checking the Wilcom data in another database server. So the is not matching with it.
So Database server and connections need to be changed to the database which NEC is pointing to compare.
Resolution
Updated the database name in Ecalc package and requested NEC to change the Connection string to point the new Database server which they are currently using to compare the data.
Release Information
13332 - Release Notes - RunTime Testing from WilcomDev to POLCA